  3-349-302-03 1/4.04 gossen metrawatt gmbh metraport ? 3a folding analog multimeter 300 v cat iii 600 v cat ii iec/en 61010-1, second edition applications the multimeter is equipped with an indicator display and an electronic amplifier. it can be used in a wide variety of practical electronics applications, for example in r&d, manufacturing, equipment operation, in the test lab and for service calls, as well as for training and vocational education. description the multimeter has 46 measuring ranges for direct and alternating voltages of up to 600 v, alternating voltage levels from -40 to +62 db, direct and alternating current of up to 10 a and resistances of up to 20 m ? . it has a constant input resistance of 10 m ? in all voltage measuring ranges. the multimeter is calibrated in rms values for periodic sinusoidal quantities. it makes use of full-wave rectification for the evaluation of the arithmetic mean value. all measuring ranges can be sel ected with the central measuring range selector switch. the ranges are laid out in a clear-cut fashion around the selector switch. the measuring device and the disp lay unit are enclosed in two separate housing components which are connected to each other by means of a hinge whic h can be snapped into various positions. in this way, the ideal angle for ease of reading can be selected with the instru ment in any position. several well coordinated safety devices protect the instrument against damage caused by inco rrect operation and overloading within the specified overload limit values: ? oversized precision resistors  fuse link in combination with protective rectifier diodes  overvoltage arrester / posi tive temperature coefficient resistors (ptcs) the instrument can be operated independent of mains current with a commercially available 9 v flat cell battery. long battery service life is assured thanks to the minimal current consumption of the instrument?s electronic components. the multimeter?s rugged design provides for outstanding protection where harsh mechani cal stressing prevails. when folded together, the instrument is provided with extra mechanical protection for the measuring device, as well as for the display unit. the connector jacks are protecte d against accidental contact. suitable measurement cables with 4 mm test probes are included as standard equipment. applicable regulations and standards iec/en 61010-1:2001 vde 0411-1:2002 safety requirements for electrical equipment for measurement, control and laboratory use din en 61326 vde 0843, part 20 electrical equipment for control technology and laboratory use ? emc requirements din en 60529 din vde 0470, part 1 test instruments and test procedures ? degrees of protection provided by enclosures (ip code)  9 voltage measuring ranges, v : 100 mv, 300 mv, 1 v, 3 v, 10 v, 30 v, 100 v, 300 v and 600 v  7 current measuring ranges, a : 10 a, 100 a, 1ma, 10 ma, 100 ma, 1a and 10 a  5 resistance measuring ranges : 1 ? ... 2 k ? / 10 ? ... 20 k ? / 100 ? ... 200 k ?/ 1 k ? ... 2 m ? / 10 k ? ... 20 m ?  9 level measuring ranges : -40 db ... +62 db  high input resistance of 10 m ? for no-load voltage measurement  reflective scale in folding lid which can be tilted for easy reading and provides transport protection as well, accuracy class 1.5 =  overload protection: 600 v in all functions and range settings automatic battery sh utdown when instrume nt is folded closed
metraport ? 3a folding analog multimeter 2 gossen metrawatt gmbh characteristic values 1) the 100 mv to 10 v measuring ranges can also be used for current measurement in accordance with the following table (e.g. reverse current or insulation current). these measuring ranges are rated at accuracy class 5. frequency range at ~ : 15 ... 100 hz. same overload protection as for voltage measuring ranges. 2) measured value = displayed value + constant, 0 db 0.775 v, i.e. 1 mw at 600 ? 3) protected with ptc resistor 3) protection by means of ff 1.6a/600v ac fuse link in combination with rectifier diodes. 4) ff 16a/600v fuse link, 10 a: max. 10 minutes accuracy under reference co nditions per iec 60051/en 60051 class 1.5 for zero-frequency quan tities, class 2.5 for periodic sinusoidal quantities and class 1. 5 for resistance (intrinsic error relative to 69 mm scale length) corresponding to max. 10% intrinsic error of the measured value within the range of the exaggerated scale arc. reference conditions ambient temperature +23 c 2 k relative humidity 40 ... 60% normal position of use instrument and scale horizontal 1 measured quantity frequency 45 ... 65 hz measured quantity waveshape si ne battery voltage 7.5 v 0.1 v other influencing quantities per iec 60051/en 60051 influencing quantities a nd nominal ranges of use temperature +5 ... +23 ... +35 c limiting temperatures for accuracy +5 ... +35 c for operation 0 ... +40 c for storage -25 ... +65 c (without batteries) position additional infl uence error of max. 1% of the scale length if the scale is tilted between 0 and 120 relative to horizontal frequency additional influence error of max. 5% of full scale value in the following ranges: auxiliary voltage no additional influence error. the upper limit must be set with the potentiometer for all measuring ranges in the case of resistance measurement. series-mode interference voltage damping for v : > 60 db, ac 50 hz for v ~ : > 120 db, dc common-mode interference voltage damping > 120 db, dc and 50 hz ac other influencing quantities per iec 60051/en 60051 power supply battery operation nominal voltage: 9 v , 9 v flat cell battery per iec 6lr61 (6f22), alkaline manganese, zinc-carbon or nicd rechargeable battery. battery service life with zinc-carbon: approx. 500 hours, with alkaline manganese: approx. 1000 hours, with nicd: approx. 200 hours, in the ? x 1 range: ? of specified service life battery test pointer must be within the battery test field. voltage 1) level 2) input resistance r i overload protection to 3) constant measuring span 100 mv -20 db -40 ... 1 8 db 10 m ? / / 50 pf 600 v 300 mv -10 db -30 ... 8 db 600 v 1 v 0 db -20 ... + 2 db 600 v 3 v +10 db -10 ... + 12 db 600 v 10 v +20 db 0 ... + 22 db 600 v 30 v +30 db +10 ... + 32 db 600 v 100 v +40 db +20 ... + 42 db 600 v 300 v +50 db +30 ... + 52 db 600 v 600 v +60 db +40 ... + 62 db 600 v range current at upper range limit r i 100 mv 10 na 10 m ? 300 mv 30 na 1 v 100 na 3 v 300 na 10 v 1 a 30 v 3 a current input resistance r i voltage drop ? u overload protection to 10 a 10.0 k ? 100 mv 600 v 3) 100 a 1.0 k ? 100 mv 600 v 3) 1 ma 100.0 ? 100 mv 600 v 3) 10 ma 10.0 ? 100 mv 600 v 3) 100 ma 1.4 ? 140 mv 600 v 3) 1 a 480 m ? 0.480 v 600 v 3) 1 0 a 26 m ? 260 mv 600 v 4) resistance range reading range value at scale middle (r i ) open- circuit voltage u 0 short- circuit current i k overload protec- tion to ? x1 1 ? ... 2 k ? 45.6 ? 100mv 2.2 ma 600 v 3) ? x10 10 ? ... 20 k ? 456.0 ? 100mv 0.22ma 600 v 3) ? x 100 100 ? ... 200 k ? 4.56 k ? 100mv 22 a 600 v 3) k ? x1 1k ? ... 2 m ? 45.6 k ? 1 v 22 a 600 v 3) k ? x10 10k ? ... 20 m ? 456.0k ? 1 v 2.2 a 600 v 3) 100 mv, 3 v ... 600 v: 15 hz ... 1 khz 10 a ... 10 a: 15 hz ... 1 khz 300 mv, 1 v: 15 hz ... 200 hz
gossen metrawatt gmbh 3 metraport ? 3a folding analog multimeter fuses ranges to 1 a and ? ff 1.6a/600v, 6 mm x 32 mm in combination with rectifier diodes for the 10 a ... 1 a and ? x1 ... k ? x10 ranges, switching capacity: 50 ka at 600 v~ 10 a range ff 16a/600v ac, 6 mm x 32 mm, switching capacity: 50 ka at 600 v~ electrical safety safety class ii per iec/en 61010-1:2001/vde 0411- 1:2002 measuring category ii iii operating voltage 600 v 300 v fouling factor 2 test voltage 3.5 kv~ per iec/en 61010-1:2001/ vde 0411-1:2002 electromagnetic compatibility (emc) interference emission en 61326:2002 class b interference immunity en 61326:2002 iec 61000-4-2:1995/a1:1998, feature b 8 kv atmospheric discharge 4 kv contact discharge iec 61000-4-3:1995/a1:1998, feature b 3 v/m mechanical design protection housing: ip 40, connector jacks: ip 20 dimensions 146 x 118 x 44 mm (folded closed) weight approx. 0.45 kg without battery standard equipment 1multimeter 1 9 v battery 1 ks17 measurement cable 1 set operating instructions order information for additional information regarding accessories please see:  measuring instruments and testers catalog ? www.gossenmetrawatt.com accessories sm16 current measuring adapter hv3 high-voltage probe hv30 high-voltage probe description type article number folding analog multimeter for demanding requirements metraport ? 3a m113a consumable materials fuse link (shipped in package of 10) ff(ur)1.6a/700v ac z109e fuse link (shipped in package of 10) ff(ur)16a/600v ac z109a accessories carrying pouch f822 gty 3172 095 p01 current measuring adapter for safe, trouble-free measurement of current consumption via the mains plug of connected power consumers sm16 gtm 9070190e0002 high-voltage probe, 3 kv/3 v, , also suitable as low pass filter for frequency converter signals hv3 gtz 3431 001r0011 high-voltage probe, 30 kv / 30 v dc, for safe measure- ment of direct voltage of up to 30 kv hv30 gtz 3431 001r0001 temperature probes with integrated or plug-on sensors (see measuring instruments and testers catalog) z3431... gtz 3431...
gossen metrawatt gmbh thomas-mann-str. 16 - 20 90471 nrnberg, germany edited in germany  subject to change without notice  pdf version available on the internet metraport ? 3a folding analog multimeter phone: +49-(0)-911-8602-0 fax: +49-(0)-911-8602-669 e-mail: info@gossenmetrawatt.com www.gossenmetrawatt.com without restriction as of 50 a current measuring accessories suitable for metraport all current sensors and transformers are equipped with a connecto r cable (1.2 to 1.5 m long) wi th 4 mm safety banana plugs type designation measuring range meas. category max. wire dia. transformation ratio frequency range intrinsic error (% rdg. + ...) article number 3a ac/dc current sensors with voltage output Z201A clip-on current sensor with battery mode (30 h) 0.01 ... 20 a~/30 a? 300 v / cat iii 19 mm 100 mv/a dc ... 400 hz ... 20 khz 1% + 0.002 a Z201A z202a clip-on current sensor with 2 measuring ranges, battery mode (50 h) 0.1 ... 20 a~/30 a?, 1 ... 200 a~/300 a? 300 v / cat iii 19 mm 10 mv/a, 1 mv/a dc ... 2 khz ... 10 khz 1% + 0.03 a, 1% + 0.3 a z202a z203a clip-on current sensor with 2 measuring ranges, battery mode (50 h) 1 ... 200 a~/300 a?, 1 ... 1000 a~/a? 300 v / cat iii 31 mm 1 mv/a dc ...10 khz 1% +0.5 a z203a z13b clip-on current sensor with 2 measuring ranges, battery mode (50 h) 0,2 ... 40 a~/60 a?, 0.5 ... 400 a~/600 a?, 300 v / cat iv 50 mm 10 mv/a, 1 mv/a dc ... 65 hz ... 10 khz 1.5% + 0.5 a 2.5% z13b ac current sensors with voltage output wz12b clip-on current sensor 10 ma~ ... 100 a~ 300 v / cat iii 15 mm 0.1 mv/ma 45 ... 65 ... 500 hz 1.5% +0.1 ma z219b wz12c clip-on current sensor with 2 measuring ranges 1 ma~ ... 15 a~, 1 ... 150 a~ 300 v / cat iii 15 mm 1 mv/ma, 1 mv/a 45 ... 65 ... 400 hz 3% + 0.15 ma, 2% + 0.1 a z219c wz11b clip-on current sensor with 2 measuring ranges 0.5 ... 20 a~, 5 ... 200 a~ 600 v / cat iii 20 mm 100 mv/a, 10 mv/a 30 .. .48 ... 65 ... 500 hz 1 ... 3% z208b z3512a clip-on current sensor with 4 measuring ranges 1 ma ... 1/10 a~ 100/1000 a~ 600 v / cat iii 52 mm 1 v/a, 100 mv/a, 10 mv/a, 1 mv/a 10 ... 48 ... 65 ... 3 khz 0.5 ... 3%, 0.2 ... 1% z225a af033a amp flex flexible current sensor with 2 measuring ranges, battery (150 h) 5 ... 30 a~, 5 ... 300 a~ 1000 v / cat iii length 600 mm 100 mv/a, 10 mv/a 10 ...100 hz ... 20 khz 1% + 0.5 a, 1% +0.5 a z207a af11a amp flex flexible current sensor, battery (150 h) 5 ... 1000 a~ 1000 v / cat iii length 450 mm 1 mv/a 10 ...100 hz ... 20 khz 1% + 2 a z207d af33a amp flex flexible current sensor with 2 measuring ranges, battery (150 h) 5 ... 300 a~, 5 ... 3000 a~ 1000 v / cat iii length 900 mm 10 mv/a, 1 mv/a 10 ...100 hz ... 20 khz 1% + 0.5 a, 1% + 2 a z207b af101a amp flex flexible current sensor with 2 measuring ranges, battery (150 h) 5 a~... 1 k a~, 50 a~... 10 k a~ 1000 v / cat iii length 1200 mm 1 mv/a, 0.1 mv/a 10 ...100 hz ... 20 khz 1% + 2 a, 1% + 10 a z207c ac current transformer with current output wz12a clip-on current transformer 15 ... 180 a~ 300 v / cat iii 15 mm 1 ma/a 45 ... 65 ... 400 hz 3% z219a wz12d clip-on current transformer 30 ma ... 150 a~ 300 v / cat iii 15 mm 1 ma/a 45 ... 65 ... 500 hz 2.5% +0.1 ma z219d wz11a clip-on current transformer 1 ... 200 a~ 600 v / cat iii 20 mm 1 ma/a 48 ... 65 ... 400 hz 1 ... 3% z208a z3511 clip-on current transformer 4 ... 500 a~ 600 v / cat iii 30 x 63 mm 1 ma/a 48 ... 65 ... 1 khz 3% +0.4 a gtz 3511 000 r0001 z3512 clip-on current transformer 0.5 ... 1000 a~ 600 v / cat iii 52 mm 1 ma/a 30 .. .48 ... 65 ... 5 khz 0.5% ... 0.7% gtz 3512 000 r0001 z3514 clip-on current transformer 1 ... 2000 a ~ 600 v / cat iii 64 x 150 mm 1 ma/a 30 .. .48 ... 65 ... 5 khz 0.5% +0.1 a gtz 3514 000 r0001 wz11/12 ... z201 ... z203 z13b